Atlanta Data Center
Location: Atlanta, Georgia USA
Our Atlanta location operates out of a private carrier-class data center in downtown Atlanta, Georgia.
The data center offers complete redundancy in power, HVAC, network connectivity, and security.
The data center facility is serviced through multiple power grids, with full UPS battery backup power and diesel
generators on-site. Our network is supplied by several separate networks including, SAVVIS, Global Crossing, TeliaSonera and PCCW
and is supplemented by local peering.
Why Atlanta?
Clients located anywhere in the South-Eastern United States will experience the lowest latency to our
Atlanta location.
Backbone Carriers
SAVVIS
Global Crossing
TeliaSonera
PCCW
Peering
Fire Suppression System
A state-of-the-art fire suppression system constantly monitors the physical environment for smoke, chemicals and other hazardous
materials that might spark a fire. In the case of a fire emergency, the VESDA smoke detection system would trigger the preaction
alarm, before any water is released, allowing the alarm to be handled using the best available means by our onsite technicians.
If the fire cannot be contained, water is released only after an Emergency Power Off has been initiated.
Redundant and Precise HVAC System
Temperature control is critical in maintaining fast, efficient performance from our equipment. Our facilities are built completely N+1
redundant and are cooled by multiple Liebert HVAC units, which pipe glycol-cooled air through ducted air flows and provide cold air
precisely where it is needed - at the intake of our enterprise-class server hardware. The Liebert HVAC system delivers constant,
ideal air conditions, between 68 and 74 degrees Fahrenheit and between 40% and 50% relative humidity at all times.
Our HVAC system uses efficient and effective chilled water cooling, not a standard forced/chilled air configuration.
Our HVAC systems maintain a minimum of N+1 redundancy, allowing the data center to maintain a constant, cool environment that is conducive
to our customers' mission-critical operations.
Redundant Power and UPS
The power systems are equipped with a level of redundancy that guarantees continuous operation. To ensure that the data center is
always operational all the time, a multi-layer power generation system, using some of the highest grade equipment available, is in
place. Redundant power is guaranteed by a DC power plant, 2 UPS systems and a rooftop diesel backup generator.
Unlike some other data centers the climate control and security measures are also backed up with redundant power to ensure clean
operation during power outages.
Security
Visual confirmation and strict sign-in procedures, both conducted by trained security personnel, along with key cards,
and photo ID verification ensure that only authorized personnel have access to our data center. Our staff is on-site 24/7. In
addition, all aspects of the data center are monitored and recorded via color, hi-resolution digital video cameras. All video footage
is kept on hand for a period of at least 30 days. Additionally, all network infrastructure is caged for separate "as needed only"
access by our onsite technicians.
|
|
|